index 633ac35..ad22153 100644
--- a/spaghetti-monster/anduril/anduril-manual.txt
+++ b/spaghetti-monster/anduril/anduril-manual.txt
@@ -137,14 +137,15 @@ While the light is on, a few basic actions are available:
- 5C: Go to momentary mode.
- 5H: Start a sunset timer. Details are below in the Sunset Timer section.
- - 7C: Go to ramp config mode.
+ - 7H: Go to ramp config mode.
- 10C: Activate manual memory and save the current brightness.
- Or, if it was already set to the current brightness, deactivate
- manual memory and go back to automatic memory.
- - 10H: Configure the manual memory timer, on lights where it is
- supported. Otherwise, if not supported, 10H goes back to
- automatic memory.
+ - 10H: Manual memory config menu.
+ - Item 1: Disable manual memory and go back to automatic memory.
+ (doesn't matter what value the user enters at the prompt)
+ - Item 2: Configure the manual memory timer.
+ Sets the timer to N minutes, where N is the number of
+ clicks. A value of 0 (no clicks) turns the timer off.
The "automatic" vs "manual" memory modes change the level the light goes
to with 1 click from off. In automatic mode, it uses the last
@@ -250,7 +251,7 @@ In all of these modes, some basic actions are available:
Additionally, in battery check and temperature check modes:
- - 7 clicks: Go to the voltage config mode or thermal config mode.
+ - 7H: Go to the voltage config mode or thermal config mode.
In more detail, this is what each blinky / utility mode does:
@@ -426,28 +427,27 @@ Every config mode has the same interface. The menu has one or more
options the user can configure, and it will go through them in order.
For each menu item, the light will follow the same pattern:
- - Blink one or more times, corresponding to the item number.
+ - Blink once, then go to a lower brightness. The user can keep
+ holding the button to skip this menu item, or release the button to
+ dive in and enter a new value.
- - Stutter or "buzz" quickly between two brightness levels for a few
- seconds. This indicates that the user can click one or more times
- to enter a number. It will keep buzzing until the user stops
- clicking, so there is no need to hurry.
+ - If the user released the button:
- - Pause, and then go to the next option.
+ - Stutter or "buzz" quickly between two brightness levels for a few
+ seconds. This indicates that the user can click one or more times
+ to enter a number. It will keep buzzing until the user stops
+ clicking, so there is no need to hurry.
-After the light has gone through all of the menu options, it should
-return to whatever mode the light was in before entering the config
-mode.
-
-If the user doesn't press a button during a menu item's "buzz" phase,
-that item remains unchanged from its previous value.
+After entering a number, or after skipping every menu item, it waits
+until the button is released then exits the menu. It should return to
+whatever mode the light was in before entering the config mode.
Ramp Config Mode
----------------
-While the light is on in a ramping mode, click 7 times to enter the
-config mode for the current ramp.
+While the light is on in a ramping mode, click 7 times (but hold the
+final click) to enter the config mode for the current ramp.
Or, to access the ramp config for Simple UI, make sure the Simple UI is
not active, then do a 10H action from Off.
@@ -603,7 +603,7 @@ Off Full 7C Aux LEDs: Next pattern
Off Full 7H Aux LEDs: Next color
Off Full 10C Enable Simple UI
Off Simple 10H Disable Simple UI
-Off Full 10H Simple UI ramp config menu
+Off Full 10H Simple UI ramp config menu (1: floor, 2: ceiling, [3: steps])
Off Any 13H Factory reset (on some lights)
Off Any 15+C Version check
@@ -617,10 +617,9 @@ Ramp Any 3H Tint ramping (on some lights)
Ramp Any 4C Lockout mode
Ramp Full 5C Momentary mode
Ramp Full 5H Sunset timer on, and add 5 minutes
-Ramp Full 7C Ramp config mode
-Ramp Full 10C Toggle manual memory on/off at current brightness
-Ramp Full 10H Manual memory timer config menu
-Ramp Full 10H Disable manual memory (if manual mem timer not compiled in)
+Ramp Full 7H Ramp config mode (1: floor, 2: ceiling, [3: steps])
+Ramp Full 10C Turn on manual memory and save current brightness
+Ramp Full 10H Manual memory config menu (1: off, 2: set timeout)
Lockout Any 1C/1H Momentary moon (lowest floor)
Lockout Any 2C/2H Momentary moon (highest floor, or manual mem level)
@@ -629,8 +628,7 @@ Lockout Any 4H On (ramp mode, floor level)
Lockout Any 5C On (ramp mode, ceiling level)
Lockout Full 7C Aux LEDs: Next pattern
Lockout Full 7H Aux LEDs: Next color
-Lockout Full 10C Auto-lock config menu
-Lockout Full 10H Disable Auto-lock
+Lockout Full 10H Auto-lock config menu (1: set timeout)
Strobe (any) Full 1C Off
Strobe (any) Full 2C Next strobe mode
@@ -646,7 +644,7 @@ Lightning Full 1H Interrupt current flash or start new one
Batt check Any 1C Off
Batt check Full 2C Next blinky mode (Beacon, SOS, Temp check)
-Batt check Full 7C Voltage config mode
+Batt check Full 7H Voltage config mode
Beacon Full 1C Off
Beacon Full 1H Configure beacon timing
@@ -657,10 +655,12 @@ SOS Full 2C Next blinky mode (Temp check, Batt check)
Temp check Full 1C Off
Temp check Full 2C Next blinky mode (Batt check)
-Temp check Full 7C Thermal config mode
+Temp check Full 7H Thermal config mode
Momentary Full Any On (until button is released)
Momentary Full Disconnect power Exit Momentary mode
-Config modes Full None Skip current item with no changes
-Config modes Full 1+C Enter new numeric value for current item
+Config modes Full Hold Skip current item with no changes
+Config modes Full Release Configure current item
+
+Number entry Full Click Add 1 to value for current item