diff options
Diffstat (limited to 'spaghetti-monster/anduril/anduril-manual.txt')
| -rw-r--r-- | spaghetti-monster/anduril/anduril-manual.txt | 156 |
1 files changed, 93 insertions, 63 deletions
diff --git a/spaghetti-monster/anduril/anduril-manual.txt b/spaghetti-monster/anduril/anduril-manual.txt index 66a2005..faa8b19 100644 --- a/spaghetti-monster/anduril/anduril-manual.txt +++ b/spaghetti-monster/anduril/anduril-manual.txt @@ -54,7 +54,33 @@ Simple UI has all the basic functions needed to work as a flashlight, but the minimum and maximum brightness are limited to make it safer, and any complex or advanced functions are blocked. -The button mappings for changing between the two modes are: +Functions available in Simple UI include: + + - 1C: On / off + - 1H: Ramp up (or down, if button was released less than a second ago) + - 2H: If light is on : ramp down + If light is off: momentary high mode + - 2C: Double click to go to / from highest safe level + - 4C: Lockout mode. + +Some other modes and functions are available too. When the light is +off, these are the options: + + - 3C: Battery check mode. (displays voltage once, then turns off) + - 4C: Lockout mode. + - 10H: Switch to Advanced UI. + - 15C or more: Version check. + +In Lockout mode with Simple UI, there are a few functions: + + - 1H: Momentary moon + - 2H: Momentary low + - 4C: Unlock and turn on + - 4H: Unlock and turn on at low level + - 5C: Unlock and turn on at high level + +To change between Simple UI and Advanced UI, turn the light off and then +do one of these: In Simple UI: - 10H: Go to Advanced UI. @@ -63,31 +89,28 @@ The button mappings for changing between the two modes are: - 10C: Go to Simple UI. - 10H: Configure Simple UI. -Simple UI is also enabled after each factory reset. +If you get lost, or if you want to auto-calibrate the temperature +sensor, do a factory reset. The process for this is: -Functions available in Simple UI include: + - Loosen tailcap + - Hold button + - Tighten tailcap + - Keep holding button for about 4s - - 1C: On / off - - 1H, 2H: Ramp up / down - - 2C: Double click to go to / from highest safe level - - 4C: Lockout mode. +The light should flicker while getting brighter, then briefly burst to +full power. Hold until it reaches full power to do a reset, or let go +of the button early to abort. -If you get lost, or if you want to auto-calibrate the temperature -sensor, do a factory reset. The process for this is: Loosen tailcap, -hold button, tighten tailcap, keep holding button for about 4s. The -light should flicker while getting brighter, then briefly burst to full -power. Hold until it reaches full power to do a reset, or let go of the -button early to abort. +On some lights, like products where the tailcap method is impossible, +use 13H from Off to do a factory reset. If this is difficult, try +counting it like music to make it easier: -Some other modes and functions are available too. When the light is -off, these are the options: + 1 2 3 4 + 1 2 3 4 + 1 2 3 4 + HOLD - - 3C: Battery check mode. - - 4C: Lockout mode. - - 10H: Enable Advanced UI. - - 13H: On some lights, this does a factory reset. - (usually only if the regular method is physically impossible) - - 15C or more: Version check. +Simple UI is enabled after each factory reset. Advanced UI @@ -141,7 +164,7 @@ While the light is on, a few actions are available: - 5C: Go to momentary mode. - 5H: Start a sunset timer. Details are below in the Sunset Timer section. - - 7H: Go to ramp config mode. + - 7H: Ramp config menu. - Item 1: Floor level. - Item 2: Ceiling level. - Item 3: Number of steps (except for smooth ramp). @@ -166,6 +189,13 @@ from off. There are three types of brightness memory to choose from: off for a longer time. The timer for this is configurable from 0 to 255 minutes. +Another way to think of it is: There are three styles of memory for the +last-ramped brightness level... + + - Always remember (automatic) + - Remember for N minutes (hybrid) + - Never remember (manual) + To choose a memory style, set the configuration accordingly: mem type manual mem manual mem timer @@ -263,9 +293,9 @@ always starts at battery check and the user can proceed to other blinky modes if Advanced UI is enabled. The sequence is: - Battery check. + - Temperature check (if light has a temperature sensor). - Beacon mode. - SOS mode (if enabled). - - Temperature check (if light has a temperature sensor). In all of these modes, some basic actions are available: @@ -274,7 +304,7 @@ In all of these modes, some basic actions are available: Additionally, in battery check and temperature check modes: - - 7H: Go to the voltage config mode or thermal config mode. + - 7H: Go to the voltage config menu or thermal config menu. In more detail, this is what each blinky / utility mode does: @@ -288,7 +318,7 @@ In more detail, this is what each blinky / utility mode does: A "zero" digit is represented by a very quick blink. - Voltage config mode has one setting: + The voltage config menu has one setting: 1. Voltage correction factor. This adjusts the battery measurement sensor, allowing the user to add or subtract up to @@ -308,6 +338,26 @@ In more detail, this is what each blinky / utility mode does: 12C: +0.25V 13C: +0.30V + Temperature check: + + Blinks out the current temperature in degrees C. This number + should be pretty close to what a real thermometer says. If not, it + would be a good idea to enter the thermal config menu and calibrate + the sensor. Or let the light settle to room temperature, then use + factory reset to auto-calibrate the sensor. + + The thermal config menu has two settings: + + - Current temperature. Click once per degree C to calibrate the + sensor. For example, if the ambient temperature is 21 C, then + click 21 times. + + - Temperature limit. This sets the maximum temperature the light + can reach before it will start doing thermal regulation to keep + itself from overheating. Click once per degree C above 30. For + example, to set the limit to 50 C, click 20 times. The default + is 45 C, and the highest value it will allow is 70 C. + Beacon mode: Blinks at a slow speed. The light stays on for 100ms, and then @@ -332,26 +382,6 @@ In more detail, this is what each blinky / utility mode does: The last-ramped brightness in Ramping Mode determines the brightness of SOS Mode. - Temperature check: - - Blinks out the current temperature in degrees C. This number - should be pretty close to what a real thermometer says. If not, it - would be a good idea to click 7 times to enter thermal config mode, - and calibrate the sensor. Or let the light settle to room - temperature, then use factory reset to auto-calibrate the sensor. - - Thermal config mode has two settings: - - - Current temperature. Click once per degree C to calibrate the - sensor. For example, if the ambient temperature is 21 C, then - click 21 times. - - - Temperature limit. This sets the maximum temperature the light - can reach before it will start doing thermal regulation to keep - itself from overheating. Click once per degree C above 30. For - example, to set the limit to 50 C, click 20 times. The default - is 45 C, and the highest value it will allow is 70 C. - Strobe / Mood Modes ------------------- @@ -443,12 +473,12 @@ To exit this mode, physically disconnect power by unscrewing the tailcap or battery tube. -Configuration Modes +Configuration Menus ------------------- -Every config mode has the same interface. The menu has one or more -options the user can configure, and it will go through them in order. -For each menu item, the light will follow the same pattern: +Every config menu has the same interface. It has one or more options +the user can configure, and it will go through them in order. For each +menu item, the light follows the same pattern: - Blink once, then go to a lower brightness. The user can keep holding the button to skip this menu item, or release the button to @@ -463,14 +493,14 @@ For each menu item, the light will follow the same pattern: After entering a number, or after skipping every menu item, it waits until the button is released then exits the menu. It should return to -whatever mode the light was in before entering the config mode. +whatever mode the light was in before entering the config menu. -Ramp Config Mode +Ramp Config Menu ---------------- While the light is on in a ramping mode, click 7 times (but hold the -final click) to enter the config mode for the current ramp. +final click) to access the config menu for the current ramp. Or, to access the ramp config for Simple UI, make sure the Simple UI is not active, then do a 10H action from Off. @@ -663,7 +693,7 @@ Ramp Any 3H Tint ramping (on some lights) Ramp Any 4C Lockout mode Ramp Full 5C Momentary mode Ramp Full 5H Sunset timer on, and add 5 minutes -Ramp Full 7H Ramp config mode (1: floor, 2: ceiling, [3: steps]) +Ramp Full 7H Ramp config menu (1: floor, 2: ceiling, [3: steps]) Ramp Full 10C Turn on manual memory and save current brightness Ramp Full 10H Manual memory config menu (1: off, 2: set timeout) @@ -689,24 +719,24 @@ Biking Full 1H/2H Brighter / dimmer Lightning Full 1H Interrupt current flash or start new one Batt check Any 1C Off -Batt check Full 2C Next blinky mode (Beacon, SOS, Temp check) -Batt check Full 7H Voltage config mode +Batt check Full 2C Next blinky mode (Temp check, Beacon, SOS) +Batt check Full 7H Voltage config menu + +Temp check Full 1C Off +Temp check Full 2C Next blinky mode (Beacon, SOS, Batt check) +Temp check Full 7H Thermal config menu Beacon Full 1C Off Beacon Full 1H Configure beacon timing -Beacon Full 2C Next blinky mode (SOS, Temp check, Batt check) +Beacon Full 2C Next blinky mode (SOS, Batt check, Temp check) SOS Full 1C Off -SOS Full 2C Next blinky mode (Temp check, Batt check) - -Temp check Full 1C Off -Temp check Full 2C Next blinky mode (Batt check) -Temp check Full 7H Thermal config mode +SOS Full 2C Next blinky mode (Batt check, Temp check, Beacon) Momentary Full Any On (until button is released) Momentary Full Disconnect power Exit Momentary mode -Config modes Full Hold Skip current item with no changes -Config modes Full Release Configure current item +Config menus Full Hold Skip current item with no changes +Config menus Full Release Configure current item Number entry Full Click Add 1 to value for current item |
