diff options
Diffstat (limited to 'spaghetti-monster/anduril/anduril-manual.txt')
| -rw-r--r-- | spaghetti-monster/anduril/anduril-manual.txt | 6 |
1 files changed, 4 insertions, 2 deletions
diff --git a/spaghetti-monster/anduril/anduril-manual.txt b/spaghetti-monster/anduril/anduril-manual.txt index b415972..82a76a9 100644 --- a/spaghetti-monster/anduril/anduril-manual.txt +++ b/spaghetti-monster/anduril/anduril-manual.txt @@ -113,7 +113,8 @@ There are four ways to access ramping mode when the light is off: - 1H: Turn on at the floor level. Let go after the light turns on to stay at the floor level, or keep holding to ramp up. - 2C: Turn on at the ceiling level. - - 2H: Turn on at the ceiling level, then ramp down. + - 2H: Turn on at the ceiling level, turn off when released. + (momentary high mode) While the light is on, a few basic actions are available: @@ -565,7 +566,7 @@ Mode UI Button Action Off Any 1C On (ramp mode, memorized level) Off Any 1H On (ramp mode, floor level) Off Any 2C On (ramp mode, ceiling level) -Off Any 2H On (ramp mode, ceiling level, then ramp down) +Off Any 2H On (momentary ceiling level) Off Any 3C Lockout mode Off Full 3H Strobe mode (whichever was used last) Off Any 4C Battcheck mode @@ -602,6 +603,7 @@ Lockout Full 7H Aux LEDs: Next color Strobe (any) Full 1C Off Strobe (any) Full 2C Next strobe mode +Strobe (any) Full 3H Tint ramping (on some lights) Strobe (any) Full 5C Momentary mode (using current strobe) Candle Full 1H/2H Brighter / dimmer |
